AW-YHDL012-C12

7SP062956

DisplayC5
Alarm code meaningCapacity not set or missing jumper on indoor board
DisplayE1
Alarm code meaningHigh Pressure cut off
DisplayE2
Alarm code meaningIndoor exchanger anti freeze protection
DisplayE3
Alarm code meaningLow pressure cut off (case installation multisplits 4 and 5 indoors)
DisplayE4
Alarm code meaningCompressor over heating protection
DisplayE5
Alarm code meaningOver current protection
DisplayE6
Alarm code meaningNo communication between indoor and outdoor unit
DisplayE8
Alarm code meaningindoor or outdoor unit exchanger over heating
DisplayEE
Alarm code meaningEEPROM empty or damaged
DisplayEU
Alarm code meaningIPM module over heating
DisplayF0
Alarm code meaningRefrigerant circuit problem
DisplayF1
Alarm code meaningIndoor ambiant temperature sensor RT2 disconnected or short circuited
DisplayF2
Alarm code meaningIndoor exchanger temperature sensor RT1 disconnected or short circuited
DisplayF3
Alarm code meaningOutdoor ambiant temperature sensor RT2 disconnected or shrot circuited
DisplayF4
Alarm code meaningOutdoor exchanger temperature sensor RT1 disconnected or short circuited
DisplayF5
Alarm code meaningDischarge temperature sensor T3 disconnected or short circuited
DisplayF6
Alarm code meaningReduction of compressor frequency due to an overload
DisplayF8
Alarm code meaningReduction of frequency due to overcurrent
DisplayF9
Alarm code meaningDecrease in frequency due to excessively high supply air temperature
DisplayFH
Alarm code meaningInternal exchanger frost protection
DisplayH1
Alarm code meaningDefrosting or oil return procedure on going
DisplayH10
Alarm code meaningDecreasing frequency due to overheating of the indoor exchanger
DisplayH2
Alarm code meaningESF Electro Static Filter Protection
DisplayH3
Alarm code meaningCompressor overload protection
DisplayH4
Alarm code meaningAbnormal operating conditions of system (Outdoor ambiant Temp too high, dirty exchanger…)
DisplayH5
Alarm code meaningInverter module protection
DisplayH6
Alarm code meaningNo fan motor feedback on indoor unit board
DisplayH7
Alarm code meaningCompressor desynchronisation
DisplayHC
Alarm code meaningPFC module protection
DisplayLc
Alarm code meaningFaulty start up
DisplayP5
Alarm code meaningOvercurrent protection on compressor phases
DisplayP7
Alarm code meaningPCB temperature sensor disconnected or short circuited
DisplayP8
Alarm code meaningHeat Sink module over heating (power board)
DisplayPH
Alarm code meaningDC over voltage
DisplayPL
Alarm code meaningDC voltage too low
DisplayPU
Alarm code meaningFaulty capacitors charging
DisplayU1
Alarm code meaningCompressor phase problem
DisplayU3
Alarm code meaningVoltage drop on communication bus
DisplayU5
Alarm code meaningAlternating current (AC) detection problem
DisplayU7
Alarm code meaningReversing valve blocked
DisplayU8
Alarm code meaningZero crossing protection on indoor unit
DisplayU9
Alarm code meaningZero crossing protection on outdoor unit